This 150cm LED-tube is ideally suited for use in the company. Anywhere where a high light output is required, this LED-tube will convince you. With an efficiency of 125 Lumens per Watt electricity and a color rendering index of RA 82 this 4000 Kelvin LED-fluorescent-tube (840) is well suited for offices, agencies, doctor practices and retail shops.
This G13 LED-tube is available in a clear or frosted lamp cover.
Simple installation or retrofit replacement of fluorescent tubes in fixtures with conventional ballast or low loss ballasts. The LED starter / LED-ballast is included.
High luminous flux of 3717 Lumens and a colour rendering index of RA 82 (comparison: a 60 watts light bulb creates around 700Lumen light output)
Very good efficiency values of this T8 LED-tube with 125 Lumens / watt electricity
Realistic life-time far over 30.000 hours ( 8.,5 years with a 10 hours working day)
Replaces conventional 58 watts fluorescent tube
Ideal LED-tube to connect directly to suited LED-fixtures with direct power connection and without ballast. This eliminates the additional losses of the ballast as well (between 15-25 watts in traditional neon tube fixtures) These are often LED-workplace luminaires and diffuser luminaires for damp interiors.
Saves electricity up to 60% compared to traditional fluorescent tubes. Plus a much better light quality than before.
The LED tube has a very good power factor of 0.98 and therefore does not produce unwanted reactive power.
Suited for lower operating temperatures down to -20°C and up 65°C with a low thermal emission and robustness against cold. Can be operated and installed outdoors (within IP protected fixtures against humidity) in cold storage facilities. The problem with cold starts and operation in lower temperature areas, known from fluorescent tubes does not exist with these LED-tubes.
Rotatable end-caps allow to position the exact alignment of the light source.
LED tube with G13 socket is designed to meet high professional quality demands for long-term stability, low thermal emission and constant luminosity from professional users in offices, industry, offices and retail shops. We only offer LED tubes that can meet these standards. Further advantages of LED tubes in the professional sector are savings due to extended maintenance cycles in the Facility Management. LED tubes have much longer maintenance intervals compared with conventional fluorescent tube.
Without UV light / IR component: Protects goods and goods in the salesroom LED tubes as a replacement for fluorescent lamps produce no ultraviolet light component. This means that goods, clothing or food do not fade in the retail or age faster. In addition, fewer insects are attracted by LED tubes.
Lower maintenance costs Through the use of LED tubes also reduce maintenance costs, quite worthy to be in larger companies. The frequent exchange of individual tubes or starters omitted. This includes the robustness of the LED tubes. Compared to the fluorescent housing are better protected against shocks or vibration and not break so easily.
No toxic substances: No bad conscience Compared to fluorescent LED tubes are not filled with polluting gases to be expensively disposed over the hazardous waste. LED tubes are simply disposed of as electronic waste.
Operation with motion detectors: The direct start with 100% light output plus a high switching resistance allow an even more efficient use with motion detectors.
Light data is available and can be provided.
light temperature of 4000 Kelvin (840). Creates a neutral and functional ambience. Stimulates and enhances concentration in the office. It is also used to present products and goods in the shop or retail store.
Also available as 6000 Kelvin version (860)
You want to replace your existing lighting system in a energy-efficient way? Feel free to get in contact personally. You can contact us through telephone 0049-221-9924573 during our business hours. You can also send us an e-mail through our contact form or get in contact through fax. We will respond personally.
We ship from Germany throughout Europe.
Larger quantities of G13 LED-tubes at discounted conditions can be supplied. Please get in contact.
Light data is available and can be provided to be used in light-planning applications.
Click the tab: benefits of LED tubes in office and industry
Yes! Especially in companies with long operating times of the lamps.It does not matter whether it is a company with 2 -or 500 employees. Efficiency criteria of T8 or T5 LED tubes are the daily operating-time (uptime or opening hours in retail), the much longer life of LED tubes but also the lower maintenance expense.
The four standard sizes of fluorescent tubes roughly achieve the following savings:
*The classic fluorescent lamp is always operated in conjunction with a ballast (SG **, ** ECG, CCG **). This consumes additional power and that can account for up to 15 watts per bulb. In the simple replacement of fluorescent lamp with SG against a LED tube, the ballast will continue to operate. It may be more economical to replace the entire lamp.
A personal and professional calculation is necessary. Also helpful is the demonstration of possible alternatives. Please get in contact...
** CCG = Conventional ballast (choke), SG = low loss ballast, Electronic ballast (ECG)
A normal fluorescent lamp has an average life time of about 10,000-12,000 hours. LED tubes are usually indicated with 50,000 hours or more.This is also true for the individual LEDs installed. Realistically, is an average life between 30,000-40,000 hours.This is due to the built-in electronic components (capacitors / triacs) that are subject to a quicker wear.
With very cheap LED tubes downtimes after 2-3 months can often be observed. Get advise from a competent contact person, before you purchase.
In the commercial sector with weekly working hours from 40 hours to 24-hour shift system can be quite short payback periods of 1-3 years to achieve and achieve an attractive return on the investment thereafter.
It can be assumed that the price of electricity continues to rise in the future and the calculation thus continued to develop positively. An accurate inventory of existing lighting is important. This is associated with some effort, but it pays to be very working basis.
Individual payback calculation for your LED project.Please contact us and judge us according to your individual requirements. You can reach us at 0049-221-9924573 or via our contact form
Without a doubt, rethinking is required! The change of the fluorescent tube as a pure consumables towards greater investment must be explained to the companies. Even with declining LED prices and better products, it is not worth waiting. With the currently high electricity prices, great savings can be achieved, which can eventually pay for itself. An investment in the latest technology allows you to lift a high savings now.
Are the LED tubes amortized and have achieved a significant return, you can you still invest in the next-generation of LEDs.
Compared to the classical fluorescent tube LED Tube will start immediately. Without delay and flicker. Flickering neon lights interfere with the visual perception and have a direct negative impact on the quality of work.Through the direct start, it is also possible to operate the LED tubes directly on a motion detector, because the light is available immediately at full intensity. In addition, LED tubes are insensitive to frequent switching on and off. Even the familiar humming and disturbing noise does not occur with LED tubes.
LED tubes as a replacement for fluorescent lamps produce no ultraviolet light component. This means that goods, clothing or food do not fade in the retail or age faster. In addition, fewer insects are attracted by LED tubes.
Through the use of LED tubes also reduce maintenance costs, quite worthy to be in larger companies.The frequent exchange of individual tubes or starters omitted. This includes the robustness of the LED tubes. Compared to the fluorescent housing are better protected against shocks or vibration and not break so easily.
Compared to fluorescent LED tubes are not filled with polluting gases to be expensively disposed over the hazardous waste. LED tubes are simply disposed of as electronic waste.
For companies with high power consumption is usually not charged per kilowatt-hour special on a performance-based measure of utility. It is calculated with the retrieved peak load, which is calculated mostly from the mean of the two monthly peaks.
In companies with a high percentage of machines, the reactive current issue comes into play. The reactive current is compared to the active current provided by the electricity company but can not be used. But it must be paid for it if the factor cos phi is <0.9.
This will be listed separately on the electricity bill. Good LED bulbs have a power factor> 0.95 and are not covered.Traditional fluorescent tubes with CCG have a power factor of 0.3-0.4 and usually have to be compensated by additional capacitors.
Especially in large commercial machines the theme parks reactive current is an important issue to massively save on electricity costs. Which LEDs are right for my business and what must be considered when upgrading? Please contact us and judge us according to your individual requirements. You can reach us at 0049-221-9924573 or via our contact form
Links:
Wikipedia reactive current